CD200Ignition system

release time 2019-09-12
hit count 27

General purpose digital ignition system for small engine (cylinder diameter≤190mm)

CD200 system

● Universal, low-cost, microcircuit digital ignition system for 1-12 cylinder gas engines

● Programmable configuration allows customers to choose the appropriate performance settings based on their own needs

Corresponding curve or analog signal of ignition timing and speed

Selectable Ignition Energy

Adjustable overspeed separation

Individual ignition timing adjustment per cylinder

● Comprehensive diagnosis of system faults

● Equipped with remote AC control equipment

● Windows- Monitor and configure terminal programs

● Easy installation, simple structure, suitable for any small engine.

● More economical relative to distributor ignition system.

 

CD200 ignition system with DC power supply, capacitor discharge and digital ignition is used in 1-12 cylinder small gas industrial machine, eliminating the mechanical distributor which needs to be maintained frequently, the whole system has no moving parts, has high-end control, wide application and other characteristics.

The CD200 ignition unit uses a microprocessor and is affordable. The ignition unit receives and processes angular position signals collected by a magnetic sensor, which is triggered by the sensor sensing a drilled hole or bump. This provides the engine with continuous accurate ignition timing, which is directly referenced to the engine crankshaft or camshaft.Through the use of high-energy, capacitive discharge ignition technology, CD200 ignition system can not only provide the maximum performance of the engine, but also prolong the service life of spark plugs 3-5 times compared with induction system, which has been verified by hundreds of natural gas engines all over the world.

Through the window based on the terminal program, the user can use all the characteristics of CD200, including adjustable energy output, automatic ignition timing adjustment curve (based on rotational speed or analog control input such as load sensor), over-speed setting point. The MODBUS remote terminal unit based on the software package can display primary and secondary discharge diagnostics for this system. For field use, the same system diagnostics can be obtained by the local operator through flash LEDs on the CD unit.

 

CD200 Components

COMPONENT              UNSHIELDED SYSTEM                 SHIELDED SYSTEM

CD200  Unit, 6-cylinder     791070-6                           791080-6

CD200  Unit, 8-cylinder     791070-8                           791080-8

CD200  Unit, 12-cylinder    791070-12                          —

Input Harness, 791070-x     793050-1(72”),793050-2(180”)          —

Input Harness, 791080-x     793092-1(120”)                      793091-1(shielded 48” w/180” of wire)

Output Harness(791070-6)   793048-6(72”),793090-6(180”)          —

Output Harness(791070-8)   793048-8(72”),793090-8(180”)          —

Output Harness(791070-12)  793048-6 + 793099-1(72”)              —

Output Harness(791070-12)  793090-6 + 793099-2(180”)             —

Output Harness(791080-6)   793008-6 (180” of wire, no conduit)      793014-6(shielded 48” w/180” of wire)

Output Harness(791080-8)   793008-8(180” of wire, no conduit)       793014-8(shielded 48” w/180” of wire)

Magnetic Pickup           791015-1 (3/4”-16×1.9”)              691118-2 (5/8”-18×2.50”)

                        791016-2 (3/4”-16×3.4”)              691118-3 (5/8”-18×3.00”)

                        791035-2 (M12×2.50”)                691118-1 (5/8”-18×1.75”)

                                                            691118-4 (5/8”-18×4.5”)

Magnetic Pickup Cables                                         Included in Input Harness above

                                                            593048 series (shielded 180°)﹡

                                                            593054 series (shielded 90°)﹡

Ignition Coils              501061, bule (std. duration)             501061-S shielded﹡﹡

                         591010, red (long duration)             591010-S shielded﹡﹡

                         591040, black (long duration)            591007 integral coil

                                                             591011A integral coil

                                                             591011B integral coil

﹡    See the Altronic price list for available lengths.

﹡﹡  See the Altronic price list for available secondary lesds.

Specifications

No. of cylinders﹍﹍﹍﹍﹍﹍﹍﹍1-8

Power required﹍﹍﹍﹍﹍﹍﹍﹍﹍12Vdc,1.0Amp

                                24Vdc,0.5Amp

Max.voltage output﹍﹍﹍﹍﹍﹍﹍40kV

Spark duration﹍﹍﹍﹍﹍﹍﹍﹍﹍300-600microsec.

Timing adjustment:

  Manual (8-pos. switch)﹍﹍﹍﹍user-selectable increments

  RPM range﹍﹍﹍﹍﹍﹍﹍﹍﹍﹍ 25 to 2,500RPM

  Analong input range﹍﹍﹍﹍﹍ 4-20mA or 0-5Vdc

  Overall max.timing range﹍﹍﹍25°of retard

Overspeed setpoint range﹍﹍﹍﹍25 to 2,500RPM

Output switch rating﹍﹍﹍﹍﹍﹍0.5Amp, 32Vdc max.

Communications﹍﹍﹍﹍﹍﹍﹍﹍﹍Modbus RTU(RS-485)

 

Name

Parameter

Cylinders

CD 200 ignition system

12-24V

1-12

 

CD200